Flame Atomic Absorption Spectrophotometer

Flame Atomic Absorption Spectrophotometer
Flame Atomic Absorption Spectrophotometer
Product Code : WFX-110B
Brand Name : Weiber
Product Description

Flame Atomic Absorption Spectrophotometer

Features

Innovated rich oxygen air-acetylene flame analysis technique(WFX-110B)

The patented flame analysis technique adopting rich oxygen air-acetylene flame as the substitution for nitrous oxide-acetylene flame for high temperature element analyses, such as Ca, Al, Ba, W, Mo, Ti, V, etc. Flame temperature is continuously adjustable between 2300-2950? which makes it possible to choose the best atomization temperature for different elements. It features easy operation, low analysis cost and wide flame AAS analytical range. Rich oxygen flame will not pollute the environment and is not harmful to human bodies. It's break-through in flame AAS analysis

Specification

Main Specification

Wavelength Range

190-900nm

 

Wavelength Accuracy

±0.25nm

 

Resolution

Two spectral lines of Mn at 279.5nm and 279.8nm can be separated with the spectral bandwidth of 0.2nm and valley-peak energy ratio less than 30%.

 

Baseline Stability

0.004A/30min

 

Background Correction

The D2 lamp background correction capability at 1A is better than 30 times

 

 

The S-H background correction capability at 1.8A is better than 30 times.( only for WFX-110B/120B)

 

Lamp Turret

6-lamp turret (WFX-110B/120B), 4-lamp turret (WFX-130B); Auto-alignment, fully automated scan and peak-picking.

Light Source System

Lamp Current Adjustment

400Hz square wave pulse

 

 

Wide pulse current: 0~25mA,

 

 

Narrow pulse current: 0-10mA

 

Lamp Power Supply Mode

400Hz square wave pulse;

 

 

100Hz narrow square wave pulse+400Hz wide square wave pulse (WFX-110B/120B)

Optical System

Monochomator

Single beam, Czerny-Turner design grating monochromator

 

Grating

1800 l/mm

 

Focal length

277mm

 

Blazed Wavelength

250nm

 

Spectral Bandwidth

0.1nm, 0.2nm, 0.4nm, 1.2nm, automatic change

Flame Atomizer

Burner

10cm single slot all-titanium burner

 

Spray Chamber

Corrosion resistant all-plastic spray chamber

 

Nebulizer

High efficiency glass nebulizer with metal sleeve, sucking up rate:6-7ml/min

 

Emission burner provided with WFX-110B/120B

Detection and Data Processing System

Detector

R928 Photomultiplier with high sensitivity and wide spectral range.

 

Software

Windows operating system

 

Analytical method

Working curve auto-fitting; standard addition method; automatic sensitivity correction, automatic calculation of concentration and content.

 

Multi-task Functions

Sequential measurement for multi-element determination in one sample

 

Condition reading

With model function

 

Result printing

Measurement data and final analytical report printout, editing with Excel

 

Standard RS-232 serial port communication

Characteristic Concentration and Detection Limit

Normal Air-C2H2 flame Oxygen-rich Air-C2H2 flame

Cu: Characteristic concentration=0.025mg/L, Detection limit=0.006mg/L;

 

 

Ba: Characteristic concentration = 0.22mg/L

 

 

Al: Characteristic concentration = 0.4mg/L

Function Expansion

Hydride vapor generator can be connected for hydride analysis

Dimensions and Weight

Main unit

102—49—54cm, unpacked 80kg

 



ACMAS TECHNOLOGIES PVT. LTD.
507, Pearl Best Heights II, Pitampura,Delhi - 110034, India
Mr. Atul Badola (Director)
Mr. Saudan Singh (Director)
Ms. Komal Wadhwani (Marketing Manager)
Ms. Sonia Nathani
Mr. Jay Ram Patel (IT head)
Send Inquiry


Buyers Helpdesk

Let tradeindia.com find Quality Suppliers for you!

I agree to abide by all the Terms and Conditions of tradeindia.com
ACMAS TECHNOLOGIES PVT. LTD. All Rights Reserved.