Cookie Img
Send Inquiry
Home » Products » Measuring Meters » Online Steam Sodium Analyzer

Online Steam Sodium Analyzer

Online Steam Sodium Analyzer
Online Steam Sodium Analyzer
Product Code : HK-358
Brand Name : Weiber
Product Description

Online Steam Sodium Analyzer

The Online Steam Sodium Analyzer have been modernized record online steam sodium meters. They have been most appropriate matched for modernized industrial applications, preferred for energy plants as well as alternative associated application, granted with Professional ppb turn sodium electrode that is specifically written for cation sodium measurement. Beside being rarely correct the online sodium meters have been really low maintenance. The singular underline of the meters have been tall grade of fortitude as well as Large LCD, display. These units have been row mounted for easy operation.

Features

  • Professional ppb turn sodium electrode.
  • Special designmen for cation sodium measurement.
  • The lowest upkeep of a analyzer.
  • Large LCD display.
  • The fortitude is high.
  • Low upkeep consumption.
  • The row ascent is easy for operating.


Technical Specifications

Transmitter Data

Measuring Range:

 0.00~9.36) pNa,0.01¼g/L~23.0g/L,(-1000~+1000)mV

Min. Resolution:

0.01pNa,0.01ug/L,0.1mV

 

 

Accuracy:

0.01pNa,1display byte,±0.5mV(between ±10°Cof the calibration temperature)

Stabilit

±0.01pNa/24h,±1display byte/24h,±0.5mV/24h

Current Output:

(0~10)mA or (0~20)mA or (4~20)mA(two channel isolated output)

 

 

Output Precision:

±1%F.

Max. Output loading:

800Ω

Power Supply:

(220±22)VAC, (50±1)Hz

Power Consumption:

8W

Insulation:

Line & Neutral of power supply to earth, 1500V/1minute, no flying arc

Alarm Output

high concentration alarm,low concentration alarm,high temperature alarm,low temperature alarm(the alarm value can be changed by program, two items in four can be set.)

Conmmunication:

CAN bus(optional)

Auto Data Record

It can record the history data, history event and calibration record automatically

Instrument Data

 

Measuring Range:

(1.00~8.00)pNa,  0.23ug/L~2300mg/L

Min. Resolution:

0.01pna or 0.01ug/l

Accuracy:

±0.02pna or ±0.5ug/l, the larger one (during the ±10°Cof the calibration temperature)

Responding Time:

reach 90% in 2 minutes at 25°C

Temperature Electrode:

Pt1000

 

Temperature Range:

 

Temperature Precision:

 

Temperature Resolution:

 

Temperature Compensation Range: (0.1~60.0)°C(automatic or manual)

Calibration:

sample and two points standard solution calibration.

Overall Dimension:

450W—690H—190Dmm(panel mounting)

Panel Cutout:

410mm—645mm

Weight:

20kg

Sample Data

 

Temperature:

(5~50)°C

Pressure:

( 50~300)Kpa

Flow:

(6~40)L/H

Solid allows in sample: ≤5 um (no jelly and grease in the sample)

 

Environment Data

 

Ambient Temperature:

(5~45)°C

Ambient Humidity:

‰¤90%RH (no condensation)

Transportation Temp.:

(-25~55)°C(the transportation temperature of the electrode should be higher than 0°C

 



ACMAS TECHNOLOGIES PVT. LTD.
507, Pearl Best Heights II, Pitampura,Delhi - 110034, India
Mr. Atul Badola (Director)
Mr. Saudan Singh (Director)
Ms. Komal Wadhwani (Marketing Manager)
Ms. Sonia Nathani
Mr. Jay Ram Patel (IT head)
Send Inquiry


Buyers Helpdesk

Let tradeindia.com find Quality Suppliers for you!

I agree to abide by all the Terms and Conditions of tradeindia.com
ACMAS TECHNOLOGIES PVT. LTD. All Rights Reserved.